Tarantella login scripts use and support a number of variables. Two types of variable are supported:
TTA_ResumeTimeOut
variable only exists if you've specified a value for the application
object's Resumable For
attribute.Variable | Description |
---|---|
ALTDISPLAY |
The fully qualified DNS name of the user's client device and the display number being used. |
DISPLAY |
The IP address of the user's client device and the display number being used. |
TTA_AUXCOMMANDS |
Any auxiliary commands to run on the application server. This corresponds to the application object's Window Manager attribute. |
TTA_COMMAND |
The command to run on the application server. This corresponds to the application object's Application Command attribute. |
TTA_CONNECTIONSERVICE |
The transport used to connect to the application server. This corresponds to the application object's Connection Method attribute. |
TTA_ENVIRONMENT |
Any environment variable settings required on the application server. This corresponds to the application object's Environment Variables attribute. |
TTA_HOSTNAME |
The application server that the login script connects to. This is chosen by application server load balancing, from those shown in the Hosts tab. |
TTA_IPADDRESS |
The application server's IP address. |
TTA_LOGFILE |
The name of a file in which error and diagnostic messages are
logged. By default, this is of the form
scriptID.log , where
script is the name of the login script and ID is
its process ID on the Tarantella server.
If set to null, messages aren't stored. To log messages in this file, include the code
|
TTA_PRIMARY_DNSNAME |
The primary Tarantella server's fully qualified DNS
name. This lets the login script choose the correct Tarantella
printer when setting the default printer value. It's used to
differentiate between multiple entries in the
/etc/ttaprinter.conf file.
|
TTA_WILLDISCONNECT |
Whether the connection will be broken once the command has been executed. |
TTA_AGEDPASSWORD |
Whether to use the manual or dialog method of dealing with aged passwords. |
TTA_ALLOWTHIRDTIERDIALOG |
Whether to allow a dialog box on the third tier if the user's password is aged. |
TTA_THIRD_TIER_VARS |
The list of variables to export to the environment on the application server. |
TTA_STDERR |
A temporary error file. |
Most optional variables contain the values of object attributes. The application being started has its application object's attributes made available as optional variables. Similarly, the user's person object's attributes are also available in this way.
The remaining optional variables contain additional information about the user's session.
Variable | Description |
---|---|
TTA_Appearance |
Corresponds to the application object's Border Style attribute. |
TTA_AppletHeight |
Corresponds to the application object's Application Height attribute. |
TTA_AppletWidth |
Corresponds to the application object's Application Width attribute. |
TTA_ApplicationName |
The application object's TFN name. |
TTA_ApplicationPlacement |
Corresponds to the application object's Display
Using attribute. This variable can have the values
mainbrowser (means Webtop), multiplewindows
(means Client Window Management), newbrowser (means New
Browser Window), awtwindow (means Independent Window),
kiosk (means Kiosk) and localx (means Local
X Server). |
TTA_Arguments |
Corresponds to the application object's Arguments For Command attribute. |
TTA_Autowrap |
Corresponds to the application object's Wrap Long Lines attribute. |
TTA_CachePassword |
Whether the Save This Password box was checked if the user supplied their username and password for the application server. |
TTA_CLIENT_IPADDR |
The IP address of the user's client device. |
TTA_CodePage |
Corresponds to the application object's Code Page attribute.
This variable can have the value 437 , 850 ,
852 , 860 , 863 ,
865 , 8859-1 , 8859-2 ,
Multinational , Mazovia or
CP852 . |
TTA_ColorMap |
Corresponds to the application object's Color Map attribute. |
TTA_Columns |
Corresponds to the application object's Columns attribute. |
TTA_Compression |
Corresponds to the application object's Command
Compression attribute. This variable can have the value
automatic , on or off . |
TTA_ContinuousMode |
Corresponds to the application object's Command
Execution attribute. This variable can have the value
automatic , on or off . |
TTA_ControlCode |
Corresponds to the application object's Escape Sequences
attribute. This variable can have the value 7-bit or
8-bit . |
TTA_Cursor |
Corresponds to the application object's Cursor attribute. This
variable can have the value off , block or
underline . |
TTA_CursorKeyMode |
Corresponds to the application object's Cursor Keys
attribute. This variable can have the value application
or cursor . |
TTA_DelayedUpdate |
Corresponds to the application object's Allow Delayed Updates attribute. |
TTA_DisplayEnginePage |
Corresponds to the application object's Emulator Applet Page attribute. |
TTA_DisplayName |
Corresponds to the person object's Name attribute. |
TTA_DisplayUI |
Corresponds to the application object's Display TN3270E Interface attribute. |
TTA_Domain |
Corresponds to the application object's Windows NT Domain attribute. |
TTA_EuroMapping |
Corresponds to the application object's Euro Character
attribute. This variable can have the value iso8859-15 or
unicode . |
TTA_FilePath |
Corresponds to the application object's Application Command attribute. |
TTA_FixedFontSize |
Corresponds to the application object's Fixed Font Size attribute. |
TTA_FontFamily |
Corresponds to the application object's Font Family
attribute. This variable can have the value courier ,
helvetica or timesroman . |
TTA_FontSize |
Corresponds to the application object's Font Size attribute. |
TTA_GraphicsAcceleration |
Corresponds to the application object's Use Graphics Acceleration attribute. |
TTA_Height |
Corresponds to the application object's Application
Height attribute.
This variable provides the same information as
|
TTA_HostId |
Corresponds to the 3270 application object's Session ID attribute. |
TTA_HostName |
The application server that the login script connects to. This is chosen by application server load balancing, from those shown in the Hosts tab. |
TTA_IBMHostName |
Corresponds to the 3270 application object's 3270 Host attribute. |
TTA_Icon |
Corresponds to the application object's Webtop Icon attribute. |
TTA_InstanceName |
The emulator session ID. |
TTA_InterlacedImages |
Corresponds to the application object's Interlaced
Images attribute. This variable can have the value
automatic , on or off . |
TTA_KeymapLock |
Corresponds to the application object's Lock Keymap attribute. |
TTA_KeypadMode |
Corresponds to the application object's Keypad attribute.
This variable can have the value application or
numeric . |
TTA_Lines |
Corresponds to the application object's Lines attribute. |
TTA_LocalAddr |
The IP address of the Tarantella host. |
TTA_LoginScript |
Corresponds to the application object's Login Script attribute. |
TTA_MiddleMouseTimeout |
Corresponds to the application object's Middle Mouse Timeout attribute. |
TTA_ParentName |
The application object's TFN name.
This variable provides the same information as
|
TTA_PortNumber |
Corresponds to the 3270 application object's Port Number attribute. |
TTA_ProtocolArguments |
Corresponds to the application object's Protocol Arguments attribute. |
TTA_RemoteAddr |
The IP address of the application server which is to run the application. |
TTA_RequiresDisplayEngine |
Whether or not the application requires a display engine. |
TTA_ResumeTimeOut |
Corresponds to the application object's Resumable For
attribute.
3270 application objects use |
TTA_RootColor |
Corresponds to the application object's Color attribute. |
TTA_RootType |
Corresponds to the application object's Root Window
attribute. This variable can have the value default or
color . |
TTA_ScrollStyle |
Corresponds to the application object's Scroll Style
attribute. This variable can have the value normal ,
jump or smooth . |
TTA_SecureConnection |
Corresponds to the person object's Connections attribute. |
TTA_SessionExit |
Corresponds to the application object's Session Ends When
attribute. This variable can have the value lastclient
(means Last Client Exits), windowmanager (means Window
Manager Exits), windowmanageralone (means Only Window
Manager Remains), loginscript (means Login Script Exits)
and nowindows (means No Visible Windows). |
TTA_StatusLine |
Corresponds to the application object's Status Line
attribute. This variable can have the value none ,
indicator and host writable ,
standard or extended . |
TTA_StyleFile |
Corresponds to the 3270 application object's Style File attribute. |
TTA_Suspend |
Corresponds to the application object's Resumable attribute.
This variable can have the value never ,
session (means Tarantella Webtop Session) and
forever (means Always). |
TTA_TerminalClass |
Corresponds to the application object's Emulation Type
attribute. This variable can have the value scoconsole ,
vt420 or wyse60 . |
TTA_TerminalType |
Corresponds to the application object's Terminal Type attribute. |
TTA_TimeOut |
Corresponds to the 3270 application object's Resumable For
attribute.
Other application objects use |
TTA_Transport |
Corresponds to the application object's Connection Method
attribute. This variable can have the value rexec ,
rcmd , telnet , rlogin or
ssh .
The guaranteed variable |
TTA_UserName |
The TFN name of the user this emulator session is for. |
TTA_UserSecurityEquivalent |
Corresponds to the person object's Username attribute. |
TTA_ViewHostReply |
Corresponds to the application object's Keep Launch Connection Open attribute. |
TTA_WebTop |
Corresponds to the person object's Webtop Theme attribute. |
TTA_Width |
Corresponds to the application object's Application Width
attribute.
This variable provides the same information as
|
TTA_WinCursor |
Corresponds to the application object's Use Windows Cursor attribute. |
TTA_WindowsApplicationServer |
Corresponds to the application object's Windows
Protocol attribute. This variable can have the value
wincenter , wincentermf (means Citrix UNIX
Integration Services), merge (means SCO Merge),
winframe (means WinFrame/MetaFrame), wcpwts
(means Windows Terminal Services) or
none . |
TTA_WindowsApplicationSupport |